The connection between the patient and the system
A handle that adapts to the movement
The support point must not only be accessible; its position, height and orientation must also be suited to the patient and the movement in question. The get up® grab handle can be adjusted in several directions for this purpose.
Set the grip position flexibly
Position along the system
Position the handle mount along the notched rails. This allows you to adjust the holding point, in consultation with the patient, to suit the specific movement task.
Adjust to the correct handle height
Height adjustment
Adjust the handle to any height within a range of approximately 260 mm.
Ergonomic positioning
Rotatable alignment
You can rotate the handle freely, so you can adjust its orientation to suit different grip and body positions.
Hang up the grab handle when not in use
Storage
If the handle is not required, hang it on the designated position on the system.
Lock the grab handle in position
Secure fastening
A lockable latching mechanism helps to ensure precise positioning and is designed to prevent accidental adjustment during use.
A support point that adapts to the working area
The swivelling patient transfer aid for flexible support in the working area
get up® Classic assists patients with standing up, lying down and positioning – with a support point that can be swivelled precisely to the required area. Clinicians can guide the arm towards the patient and move it out of the immediate working area again after use.
The system thus combines support, freedom of movement and adjustable positioning in a single solution. This makes get up® Classic particularly well-suited to a variety of spatial requirements in radiology and radiotherapy.
- Can be positioned precisely Move the support point to where it is needed.
- Flexibly swivelling The swivel mechanism is suitable for a variety of working and spatial situations.
- Clear working area Once you have finished using it, move the system out of the immediate work area.
- Versatile planning options A range of designs allows them to be adapted to suit different rooms.
Suitable for a variety of room layouts
Three installation options
The get up® Classic swivelling patient transfer aid is available in ceiling-mounted, wall-mounted and floor-mounted versions. MRI versions are available for the ceiling-mounted and floor-mounted configurations.
Maximum freedom within the space
get up® Classic – ceiling-mounted version
The ceiling-mounted version is the preferred solution for many projects. Install the swivel arm above the work area and move it precisely towards the examination table. The floor and walls remain unobstructed, allowing the system to integrate easily into existing workflows and equipment set-ups.
Different swivel arm lengths are available depending on the layout of the room, ensuring that the required working area is precisely covered.
Seamless integration with a suspended ceiling
Substructure and bearings above the ceiling; visible area reduced to the essentials
In this version, the get up® is fixed to the structural ceiling. The substructure, including the bearings, is located entirely above the suspended ceiling. The only visible part is the system’s feed-through. The ceiling opening is neatly covered with a ceiling trim plate, ensuring that the system blends discreetly and tidily into the room.
A compact solution for a shallow ceiling void
If there is insufficient space in the cavity above the suspended ceiling
If a suspended ceiling is present but the distance to the structural ceiling is too small to accommodate the bearing fully within the ceiling void, install a small decorative cover. It covers the visible lower section of the structure and ensures a neat and functional installation, even in confined spaces.
Solution without a suspended ceiling
Technical components concealed, integrated in a way that is both functional and aesthetically pleasing
If there is no suspended ceiling, the substructure is fitted visibly beneath the structural ceiling. To ensure a neat and high-quality finish, a large decorative cover is fitted beneath the bearing. This conceals the structure and ensures a harmonious overall appearance in the room.
360° swivel range with adjustable limits
Controlled positioning thanks to locking mechanism in 15° increments
The swivel arm locks in 15° increments, enabling controlled, repeatable positioning of the holding point. If required, you can restrict the swivel range using swivel stops to prevent collisions – for example, with walls, built-in fixtures or other obstacles in the room.
Ceiling-mounted version for MRI environments
Reliably integrated under defined operating conditions
The MRI version of the get up® system is designed for use in magnetic resonance environments under defined conditions. Manufactured from high-quality stainless steel, the system has been tested for static magnetic fields of 0.55 T, 1.5 T and 3 T. Leading MRI manufacturers and independent, accredited testing laboratories collaborated on validation.
Installation involves securely anchoring a specially designed spacer to the ceiling. The support system is galvanically isolated within the Faraday cage by means of polyamide bushings, ensuring structural stability, electrical isolation and compatibility with the sensitive MRI infrastructure.
Flexible integration, regardless of the ceiling structure
get up® Classic – wall-mounted version
The wall-mounted version of the swivelling get up® offers an alternative when ceiling mounting is not possible or practical because of the building’s layout or existing technical installations. Install the system on a suitable, load-bearing wall and swivel it into the required working area.
Wall mounting is particularly useful in X-ray rooms where the ceiling is already occupied by rail systems and other components.
Swivel range adapted to the room
Flexible positioning whilst maintaining defined movement limits
The swivel arm allows for a wide range of movement around the mounting point. Swivel stops enable precise adjustment to suit the specific layout of the room, for example to exclude walls, appliances or other fixtures from the range of movement.
You can also lock the system in place at 15° increments to secure it in defined positions.
Detect the position of the swivel arm electronically
For coordination with mobile x-ray systems
To prevent collisions with self-propelled X-ray systems, you can optionally fit the get up® with an electronic position detection system. It detects whether the patient transfer aid is in a defined position so that movement of the X-ray system within the defined range can be enabled.
Signal processing and system integration are tailored to the specific X-ray equipment manufacturer on a project-by-project basis.
See the system status at a glance
Visual feedback via LED display
LED lights indicate the system status visually. This immediately shows whether get up® is in the intended position or whether the defined range of movement is enabled. The brochure distinguishes between the status indicators ‘Locked’ and ‘Free’.
This clear indication facilitates communication between the patient transfer aid, the user and the connected X-ray system.
Long range, regardless of walls and ceilings
get up® Classic – floor-mounted version
The floor-mounted version of the get up® Classic is suitable for rooms where wall or ceiling mounting is not possible or not desired. Its floor-mounted structure allows flexible positioning of the support point and can be adapted to the requirements of each project.
With swivel arms up to 3.2 m in length, the system can bridge greater distances between the installation point and the required support area.
Independent of walls and ceilings
A modular design for flexible room layouts
The floor-standing version supports the get up® via a floor-mounted structure and therefore requires no fixing point on the wall or ceiling. It is particularly suitable for rooms where existing ceiling installations or structural conditions make other mounting options difficult.
The swivel arm positions the support point precisely within the required working area from the floor-mounted structure.
Range of up to 3.2 m
Reach large work areas from a fixed position
Depending on the room layout, we can supply the floor-mounted version with different swivel arm lengths. Arms up to 3.2 m span larger distances between the floor-mounted structure and the examination table.
This means that the unit can be positioned where it integrates most effectively into the room, whilst the holding point still reaches the required working area.
Information and product experience
Find out more. Experience it for yourself.
Request further product information or learn about our solutions during a personalised live demonstration—either in person in Oelde or online.