The get up® product range
Support tailored to the patient, the procedure and the room
Empowering patients
The patient transfer aids provide an accessible grab handle, allowing patients to use their existing mobility when standing up, lying down and repositioning.
Tailored to your needs
From simple support for standing to a full lifting function with the Multilift, a range of support levels is available.
Planned with the space in mind
We tailor the design, range and positioning to the size of the equipment, the range of movement, the ceiling structure and clinical procedures.
Can be moved out of the work area
Swivelling or telescopic versions can be positioned so that the grab handle is accessible when needed and causes as little disruption as possible to the workflow.
The operating principle
Provide support without replacing existing independent mobility
Patients vary in terms of strength, mobility and the level of support they require. Whilst some simply need a stable, easily accessible handle, others require more extensive assistance when sitting up, being moved or repositioned.
get up® provides the necessary support directly at the examination or treatment table. The patient can actively use the handle whilst staff guide and assist with the movement. Depending on the model, the patient transfer aid offers a swivel arm, adjustable reach or, with the Multilift, an integrated patient hoist.
The aim is not to automate every movement; instead, it helps patients use their existing mobility while reducing physically demanding manual assistance.
- Active participation The patient can incorporate their existing physical abilities into the movement sequence.
- Support tailored to the situation We tailor the system design to mobility requirements, intended use and spatial conditions.
Four versions, different tasks
Which get up® solution is right for your project?
Not every hospital room and not every patient requires the same kind of support. The four get up® models therefore each have a different focus.
get up® Classic
The swivelling standard version provides a flexible support point for patients and can be moved out of the immediate working area when not in use.
- Assistance with getting up and lying down
- Flexible swivel range
- For different diagnostic applications
- Project-specific versions available
get up® Multilift
The Multilift complements the holding and sitting-up functions with full lifting support for patients requiring a high level of assistance.
- Combined grab handle support and patient hoist
- Support for patients with insufficient independent mobility
- Repositioning and full lifting
- Configurable for higher load requirements
get up® Ceiling Bridge
The get up® Ceiling Bridge provides sturdy support for patients in clearly defined working areas and is tailored to the room and ceiling structure.
- Defined support area
- Project-specific version
- Integration into existing ceiling structures
- Cost-effective solution for suitable applications
Product comparison
A comparison of the get up® models
The table is intended as a guide. We will determine the specific design based on the patient’s condition, the clinical procedure, the medical equipment and the structural requirements.
get up® Classic
Model / version
| Feature | get up® Classic |
|---|---|
| MRI version available |
|
| Ceiling-mounted version |
|
| Floor-mounted version |
|
| Wall-mounted version |
|
| Lift function |
|
| Grab handle |
|
Application
| Feature | get up® Classic |
|---|---|
| CT, PET-CT, SPECT-CT |
|
| MRI |
|
| X-ray |
|
| Linear accelerator |
|
Technical specifications
| Feature | get up® Classic |
|---|---|
| Turning radius | <3.2 m |
| Max. load | 135 – 175 kg |
get up® Telescopic
Model / version
| Feature | get up® Telescopic |
|---|---|
| MRI version available |
|
| Ceiling-mounted version |
|
| Floor-mounted version |
|
| Wall-mounted version |
|
| Lift function |
|
| Grab handle |
|
Application
| Feature | get up® Telescopic |
|---|---|
| CT, PET-CT, SPECT-CT |
|
| MRI |
|
| X-ray |
|
| Linear accelerator |
|
Technical specifications
| Feature | get up® Telescopic |
|---|---|
| Turning radius | <1.7 m |
| Max. load | 135 – 175 kg |
get up® Multilift
Model / version
| Feature | get up® Multilift |
|---|---|
| MRI version available |
|
| Ceiling-mounted version |
|
| Floor-mounted version |
|
| Wall-mounted version |
|
| Lift function |
|
| Grab handle |
|
Application
| Feature | get up® Multilift |
|---|---|
| CT, PET-CT, SPECT-CT |
|
| MRI |
|
| X-ray |
|
| Linear accelerator |
|
Technical specifications
| Feature | get up® Multilift |
|---|---|
| Turning radius | <2.6 m |
| Max. load | 200–400 kg (lifting capacity) |
get up® Ceiling Bridge
Model / version
| Feature | get up® Ceiling Bridge |
|---|---|
| MRI version available |
|
| Ceiling-mounted version |
|
| Floor-mounted version |
|
| Wall-mounted version |
|
| Lift function |
|
| Grab handle |
|
Application
| Feature | get up® Ceiling Bridge |
|---|---|
| CT, PET-CT, SPECT-CT |
|
| MRI |
|
| X-ray |
|
| Linear accelerator |
|
Technical specifications
| Feature | get up® Ceiling Bridge |
|---|---|
| Turning radius |
|
| Max. load | 175 kg |
Model / version
| Feature | get up® Classic | get up® Telescopic | get up® Multilift | get up® Ceiling Bridge |
|---|---|---|---|---|
| MRI version available |
|
|
|
|
| Ceiling-mounted version |
|
|
|
|
| Floor-mounted version |
|
|
|
|
| Wall-mounted version |
|
|
|
|
| Lift function |
|
|
|
|
| Grab handle |
|
|
|
|
Application
| Feature | get up® Classic | get up® Telescopic | get up® Multilift | get up® Ceiling Bridge |
|---|---|---|---|---|
| CT, PET-CT, SPECT-CT |
|
|
|
|
| MRI |
|
|
|
|
| X-ray |
|
|
|
|
| Linear accelerator |
|
|
|
|
Technical specifications
| Feature | get up® Classic | get up® Telescopic | get up® Multilift | get up® Ceiling Bridge |
|---|---|---|---|---|
| Turning radius | <3.2 m | <1.7 m | <2.6 m |
|
| Max. load | 135 – 175 kg | 135 – 175 kg | 200–400 kg (lifting capacity) | 175 kg |
Mutual benefit
get up® from three perspectives
For patients
1. Increased safety
Reduces the risk of falls by providing a stable and secure grip.
2. Active participation
Encourages patients to carry out transfers and repositioning independently.
3. Greater comfort and dignity
Minimises unnecessary physical contact and preserves personal autonomy.
For imaging, radiotherapy and healthcare staff
1. Supporting ergonomic working practices
get up® supports patients in taking an active role when sitting up and transferring, which can reduce the manual assistance required from staff.
2. Improved ergonomic safety
It promotes healthier working postures and reduces the risk of musculoskeletal disorders.
3. Better control during movement
The support handle provides patients with a firm point of support when sitting up and transferring onto the examination table.
For hospitals
1. Reduced staff absenteeism
Can reduce absenteeism due to illness or injury and can help to stabilise workforce availability.
2. Improved operational efficiency
Supports structured, safe patient transfers and a smooth workflow.
3. Sustainable return on investment
Strengthens long-term strategies for workplace health promotion and enhances the employer’s appeal.
Technical project planning
What to clarify before specifying the system
get up® is not selected independently of the room. Structural, technical and clinical information is required to ensure a robust planning process.
Clinical application
First of all, we need to clarify:
- Which movements should be supported?
- How much independent mobility do typical patients have?
- Is a grab handle sufficient, or is an integrated patient hoist required?
- At which points in the workflow is support required?
- What patient weights need to be taken into account?
Medical equipment and working area
Examination or treatment tables, large pieces of equipment, ceiling-mounted stands, monitors and other installations determine the available ranges of movement. Relevant manufacturer’s documentation and floor plans should therefore be available at an early stage.
Structural ceiling and suspended ceiling
For ceiling-mounted systems, check the construction and load-bearing capacity of the ceiling. Factors to consider include:
- the type and material of the structural ceiling;
- the distance to the suspended ceiling and to the structural ceiling;
- existing substructures;
- services and installations on the ceiling side;
- possible fixing points;
- structural requirements
Position and range of motion
Determine the system’s position based on patient access, table positions, working routes and equipment movements. Consider where the handle is required and where to position the system when not in use.
Options and interfaces
Depending on the application, the following may be relevant, among other things:
- swivel limits;
- electronic position sensing;
- project-specific lengths;
- various handle or grip elements;
- special materials;
- electrical supply;
- Integration into device-specific safety concepts.
Confirm each option on a model-by-model basis.
Installation, training and servicing
The scope of the project may include planning, supply, installation, functional testing, training and subsequent maintenance. We define responsibilities and site requirements on a project-by-project basis.
Information
From initial information to detailed project planning
Would you like an initial overview, do you have a specific question, or are you already planning an examination or treatment room? Choose the appropriate next step.
Explore further information
Find out more about the differences between the products, consider the requirements of your department, or involve febromed at an early stage in the technical planning process.